Fluke 87 Multimeter: A Comprehensive Guide
Access four free online Fluke 87 manuals – calibration, service, and operation guides – for detailed instructions and warranty information.
The Fluke 87 is a highly regarded, professional-grade digital multimeter known for its reliability and accuracy. This instrument, detailed in comprehensive manuals available online, serves technicians and engineers across various fields. Fluke provides extensive documentation, including operation, service, and calibration manuals, ensuring users can maximize its capabilities.
These manuals cover everything from basic usage to advanced troubleshooting and repair procedures. Understanding the meter’s specifications and adhering to safety guidelines, as outlined in the documentation, is crucial for optimal performance and user safety. The Fluke 87 is designed for demanding applications, and proper utilization, guided by the official manuals, guarantees long-term functionality and precise measurements.
Historical Overview of the Fluke 87 Series
The Fluke 87 series, documented through various service and user manuals, represents a significant evolution in handheld digital multimeter technology. Initially released as a robust tool for field service, it quickly gained popularity for its durability and precision. Successive iterations – Series IV, for example – incorporated advancements in accuracy and functionality, all meticulously detailed in updated manuals.
Fluke consistently provided comprehensive documentation alongside these improvements, ensuring technicians had access to the latest calibration procedures and troubleshooting guides. The series’ longevity is a testament to its design and the ongoing support provided through readily available manuals, solidifying its place as an industry standard.
Key Features and Specifications
The Fluke 87, as outlined in its service and user manuals, boasts True-RMS accuracy for AC voltage and current measurements. It features automatic and manual ranging, alongside diode test and continuity functions with audible indication. Specifications include a maximum voltage of 1000V and current up to 10A.
Key features detailed in the documentation encompass auto hold, min/max recording, and relative measurement modes. The manuals emphasize its robust construction and safety ratings, crucial for field applications. Fluke provides detailed schematics and parts lists within the service manual, aiding repair and maintenance efforts.

Understanding the Fluke 87 Functions
Refer to the Fluke 87 user manual for detailed explanations of voltage, current, resistance, continuity, and diode testing capabilities, ensuring accurate measurements.
Voltage Measurement Capabilities
The Fluke 87 excels in voltage measurement, offering both AC and DC capabilities. The user manual details precise procedures for selecting appropriate ranges to maximize accuracy. Understanding the input impedance is crucial for accurate readings, especially in high-impedance circuits, as outlined in the service manual. Technicians should consult the manual for guidance on measuring various voltage levels, from millivolts to kilovolts. Proper probe selection and connection techniques, detailed within the operation and user’s manual, are essential for minimizing noise and ensuring reliable results. Calibration routines, found in the calibration manual, verify the voltage measurement accuracy. Always prioritize safety by adhering to the safety guidelines presented in all documentation, especially when working with potentially hazardous voltages.
Current Measurement Capabilities
The Fluke 87 provides both AC and DC current measurement, with the user manual emphasizing proper fuse selection for the chosen range. Technicians must carefully review the service manual’s section on current measurement circuits to understand limitations and potential issues. Accurate readings depend on breaking the circuit to insert the meter in series, a process detailed in the operation guide. The manual stresses the importance of using appropriate current probes for higher current measurements. Calibration procedures, outlined in the calibration manual, ensure current measurement accuracy. Always prioritize safety, as current measurements can pose significant hazards; adhere to all safety guidelines found within the documentation.
Resistance Measurement Capabilities
The Fluke 87 accurately measures resistance, with the user manual detailing the selection of appropriate ranges for varying component values. Service manuals highlight the internal resistance measurement circuitry and potential troubleshooting points. Calibration routines, as described in the calibration manual, are crucial for maintaining accuracy. Technicians should disconnect power from any circuit before measuring resistance to avoid damage to the meter or the circuit. The operation guide emphasizes that component leads should not be touched during measurement to prevent body resistance interference. Refer to the documentation for guidance on interpreting readings and verifying accuracy.
Continuity Testing Explained
The Fluke 87’s continuity function provides a quick check for complete circuits, emitting an audible tone when resistance is below a set threshold. User manuals detail how to enable and disable the beeper, adjusting sensitivity as needed. Service documentation explains the internal circuitry responsible for this feature. Calibration procedures ensure the tone activates at the correct resistance level. Always ensure power is off before testing continuity, and isolate the component being tested. The manual stresses that continuity testing isn’t a voltage or current measurement, and proper safety precautions are vital. Refer to the guide for best practices.
Diode Test Function
The Fluke 87’s diode test function applies a small forward voltage to determine if a diode is functioning correctly. Manuals explain that a healthy diode will show a forward voltage drop (typically 0.5-0.8V), while an open diode displays “OL” and a shorted diode shows near 0V. Service guides detail the test circuit’s operation. Calibration ensures accurate voltage readings during testing. Users should disconnect power and isolate the diode before testing. The manual cautions against testing in-circuit, as other components can influence results. Refer to the documentation for troubleshooting guidance and proper interpretation of readings.

Operating the Fluke 87
Follow the user manual for proper operation, including powering on/off, range selection, and utilizing the HOLD and Auto Hold functionalities effectively.
Powering On and Off
The Fluke 87 multimeter is designed for straightforward operation, beginning with its power functions. To activate the meter, rotate the rotary switch to any measurement function; this automatically powers on the device, initiating self-tests for proper functionality. The large, clear display will illuminate, confirming the meter is ready for use.
To conserve battery life, the Fluke 87 features automatic power-off functionality after a period of inactivity. Refer to the user manual for specific timeout settings. To manually power off the meter, rotate the rotary switch to the ‘OFF’ position. Always ensure the meter is completely powered down when not in use, and during storage, to maximize battery longevity and prevent accidental readings.
Selecting Measurement Ranges
The Fluke 87 offers both manual and auto-ranging capabilities for versatile measurement selection. For manual ranging, rotate the rotary switch to the desired function (voltage, current, resistance) and then select the appropriate range using the range selector button. Carefully consider the expected value of the circuit under test to choose a range that provides optimal resolution and accuracy.
Alternatively, utilize the auto-ranging function for simplified operation. In this mode, the meter automatically selects the most suitable range for the input signal. This is particularly useful when the input value is unknown or varies significantly. Refer to the user manual for detailed instructions on enabling and disabling the auto-ranging feature.
Using the HOLD Button
The Fluke 87’s HOLD button is a crucial feature for capturing and preserving a reading, especially in situations where visual observation is difficult or impossible. Pressing the HOLD button freezes the displayed value on the screen, allowing you to remove the test leads and conveniently record the measurement without losing it.
To recall the held value, simply press the HOLD button again. The display will revert to the current measurement. This function is invaluable for accessing readings in dimly lit areas or when working alone. Consult the user manual for specific details regarding HOLD button operation and potential limitations.
Auto Hold Functionality
The Fluke 87 incorporates an Auto Hold feature designed to automatically capture and display stable readings, eliminating the need for manual HOLD button activation. When enabled, the meter continuously monitors the input signal and only displays a reading when it stabilizes within a predefined tolerance.
This is particularly useful for capturing intermittent signals or when working in environments with fluctuating measurements. The Auto Hold function minimizes distractions and ensures you record only reliable data. Refer to the user manual for detailed instructions on enabling and configuring the Auto Hold settings for optimal performance.

Maintenance and Calibration
Service manuals detail routine maintenance, calibration routines, testing, troubleshooting, parts replacement, and schematics – ensuring safe operation and accuracy.
Routine Maintenance Procedures
Regular upkeep of your Fluke 87 multimeter, as outlined in the service manual, is crucial for maintaining its precision and longevity. Prioritize handling the device with care, adhering to standard practices for static-sensitive components to prevent damage. Inspect the battery compartment for corrosion and ensure proper battery contact.
Clean the exterior casing with a damp cloth, avoiding harsh chemicals or solvents. Periodically check the test leads for wear and tear, replacing them if damaged to guarantee accurate readings. Always refer to the user manual for specific cleaning recommendations and safety precautions. Following these simple procedures will help ensure reliable performance and extend the lifespan of your valuable Fluke 87.
Calibration Overview and Importance
Calibration of the Fluke 87, detailed within the calibration manual, is paramount for ensuring measurement accuracy. This process compares the meter’s readings against known standards, adjusting it to minimize errors. Regular calibration guarantees reliable results, vital for professional applications where precision is non-negotiable.
The service manual provides comprehensive calibration routines and testing procedures. Ignoring calibration can lead to inaccurate readings, potentially causing costly mistakes or safety hazards. Maintaining calibration demonstrates a commitment to quality and adherence to industry standards. Following the recommended calibration frequency, as outlined in the documentation, is essential for optimal performance.

Calibration Frequency Recommendations
The Fluke 87’s calibration frequency depends on usage and environmental conditions. Generally, annual calibration is recommended for most applications, ensuring consistent accuracy. However, more frequent calibration – perhaps every six months – is advisable for critical measurements or harsh operating environments.
Factors like temperature fluctuations, humidity, and physical shock can affect calibration stability. If the meter experiences significant impact or operates in demanding conditions, immediate recalibration is prudent. The service manual details specific guidelines, and maintaining a calibration log is highly recommended. Adhering to these recommendations maximizes the meter’s reliability and measurement integrity.
Accessing Calibration Manuals
Locating the Fluke 87 calibration manual is straightforward. Begin by searching online databases for “Fluke 87 Calibration Manual PDF.” Several websites host these documents for free viewing or download. Fluke’s official website also provides access to documentation, though navigation may require specific model number searches.
Alternatively, the service manual, often available alongside the operation manual, contains detailed calibration routines. Ensure the manual corresponds to your specific Fluke 87 Series IV version. These manuals outline step-by-step procedures, required equipment, and acceptable tolerance limits for accurate calibration, vital for maintaining measurement precision.

Troubleshooting Common Issues
Refer to the Fluke 87 service manual for specs, theory, troubleshooting, maintenance, and calibration procedures to resolve display, accuracy, or battery problems.
Display Problems and Solutions
Addressing display issues on the Fluke 87 often begins with checking the battery; a low battery can cause dim or erratic readings. The service manual details testing procedures for the LCD panel itself, identifying potential failures within the display circuitry. Inspect the internal connections and ribbon cables associated with the display, ensuring they are securely fastened and free from corrosion.
If the display remains problematic, the manual guides technicians through isolating the issue to specific components, such as the display driver IC. Troubleshooting steps include voltage checks at key test points, verifying proper signal transmission, and ultimately, component replacement if necessary. Remember to follow all safety precautions outlined in the manual when accessing internal components.
Accuracy Concerns and Verification
Maintaining accuracy is paramount with the Fluke 87. The service manual provides comprehensive calibration routines to verify performance against traceable standards. Technicians should first confirm the meter is within its specified operating temperature range, as temperature affects accuracy. Utilize precision voltage, current, and resistance sources to compare readings against known values, documenting any deviations.
The manual details acceptable tolerance limits for each measurement range. If inaccuracies are detected, proceed with calibration adjustments as outlined, carefully following the step-by-step instructions. Regular verification, as recommended in the manual, ensures continued reliability and adherence to industry standards. Proper calibration safeguards measurement integrity.
Battery Issues and Replacement
The Fluke 87 typically utilizes 9V batteries; however, the service manual details specific battery types compatible with Series IV models. Low battery indication is signaled on the display. When replacing, ensure proper polarity alignment as indicated within the battery compartment. Avoid mixing old and new batteries, and always use high-quality alkaline batteries for optimal performance.
The manual cautions against leaving depleted batteries in the meter for extended periods, as leakage can occur, causing corrosion and potential damage. After replacement, verify correct operation by powering on the device and confirming accurate readings. Refer to the user manual for detailed diagrams illustrating battery access and replacement procedures.
Fuse Replacement Procedures
The Fluke 87 service manual provides explicit instructions for fuse replacement, emphasizing the importance of using only Fluke-specified fuses. Incorrect fuse types can compromise safety and accuracy. Before attempting replacement, disconnect all test leads and power sources. Access to the fuse is typically gained by removing the meter’s case, requiring specific tools and careful handling.
The manual details the location of the fuses and their current ratings. Always replace a blown fuse with one of the exact same type and rating; never bypass or bridge a fuse. After replacement, reassemble the meter carefully and verify proper operation before use. Refer to the schematic diagrams for precise fuse locations.

Safety Information and Precautions
Always read the safety information page before servicing; follow standard practices for static-sensitive devices to ensure safe operation and retain meter condition.
General Safety Guidelines
To ensure personal safety and maintain the Fluke 87’s protective features, strictly adhere to the guidelines outlined in the user manual. Operating the meter outside of its described parameters can compromise its safety mechanisms. Always inspect the meter and test leads for any damage before each use, replacing components as needed.
Avoid using the meter in hazardous environments or with voltages exceeding its specified ratings. Never attempt to repair or modify the instrument internally unless you are a qualified technician. Remember to disconnect test leads from any live circuit before changing batteries or fuses. Prioritize safe electrical work practices and always exercise caution when working with electricity.
Understanding Safety Ratings
The Fluke 87 multimeter possesses specific safety ratings crucial for user protection. These ratings define the maximum voltage and environmental conditions under which the meter can be safely operated. Familiarize yourself with the Category III 600V and Category IV 600V ratings, understanding their implications for different measurement environments.
Ensure the meter’s safety features remain intact by avoiding applications exceeding these limits. Improper use can lead to electrical shock or damage to the instrument. Always refer to the user manual for detailed explanations of these ratings and their corresponding safety precautions. Prioritize understanding these specifications to guarantee safe and reliable operation.
Avoiding Electrical Hazards
To ensure personal safety when using the Fluke 87, always inspect the test leads for any damage before each use, replacing them if necessary. Never operate the meter with wet hands or in damp environments, as this increases the risk of electric shock. Avoid measuring voltages exceeding the meter’s specified limits.
Disconnect the circuit from power before making any resistance or continuity measurements. Always exercise caution when working with exposed circuits and adhere to established safety procedures. Refer to the user manual for comprehensive safety guidelines and warnings to mitigate potential hazards. Prioritize safety above all else during operation.

Resources and Documentation
Find user, service, and safety manuals online, alongside schematic diagrams and parts information, for both current and discontinued Fluke 87 models.
Locating User Manuals Online
Numerous online resources provide access to Fluke 87 user manuals in PDF format, offering comprehensive guidance for operation and troubleshooting. These manuals detail the meter’s functionalities, safety precautions, and proper usage techniques. Websites dedicated to test equipment often host these documents, allowing for free viewing or download. Specifically, you can find operation and user manuals for the 87 Series IV.
Fluke’s official website is a primary source, though navigating to archived documentation may require specific searches. Additionally, third-party platforms specializing in technical documentation frequently catalog Fluke manuals, ensuring accessibility for technicians and hobbyists alike. Remember to verify the manual’s relevance to your specific Fluke 87 model version for accurate information.
Finding Service Manuals
Locating the Fluke 87 service manual is crucial for in-depth repair, calibration, and troubleshooting procedures. These manuals, often available online as PDFs, contain detailed schematics, parts lists, and step-by-step instructions for servicing the instrument. Websites specializing in electronic test equipment repair frequently archive these service documents.
The Fluke 87 V/AN service manual specifically provides specifications, theory of operation, and testing procedures geared towards qualified technicians and engineers. While official Fluke resources may require registration or purchase, numerous online repositories offer free access. Always ensure the service manual corresponds to your exact model variant for accurate repair guidance and safety.
Fluke Authorized Service Centers
For professional repair and calibration services, contacting a Fluke Authorized Service Center is highly recommended. These centers employ trained technicians familiar with Fluke instruments, ensuring repairs meet stringent quality standards. To obtain warranty service, directing your product to an authorized center is often required, along with a detailed description of the issue, prepaid postage, and insurance.
Fluke’s website provides a locator tool to find the nearest authorized service center based on your location. Utilizing these centers guarantees genuine Fluke parts and adherence to proper service procedures, maintaining the instrument’s accuracy and safety. Avoid unauthorized repairs, as they may void your warranty and compromise performance.
Accessing Schematic Diagrams

The Fluke 87 service manual is the primary source for detailed schematic diagrams. These diagrams are crucial for advanced troubleshooting and repair, illustrating the intricate circuitry of the multimeter. They enable technicians to trace signal paths, identify component locations, and understand the functional relationships within the instrument.
Access to these schematics typically requires obtaining the full service manual, often available online through various technical resource websites or directly from Fluke’s documentation portal. Understanding these diagrams demands a solid foundation in electronics and circuit analysis. Proper use ensures safe and effective repair procedures, maintaining the meter’s integrity.
Parts Replacement Information
The Fluke 87 service manual provides comprehensive parts replacement information, including detailed component lists and part numbers. This is essential for sourcing correct replacements during repair procedures, ensuring compatibility and maintaining the multimeter’s accuracy. Identifying the correct part is crucial; using incorrect components can lead to malfunction or safety hazards.
Information typically includes manufacturer details for components, allowing technicians to procure replacements from authorized distributors. The manual also outlines disassembly procedures to access components safely. Always prioritize using genuine Fluke parts to uphold performance standards and warranty validity. Careful documentation of replaced parts is recommended for future reference.
Warranty Information and Service Policies
To obtain warranty service for your Fluke 87, contact a Fluke authorized service center directly. Alternatively, you can ship the multimeter, with a detailed description of the issue, postage prepaid, to the nearest authorized center. Ensure adequate insurance coverage during shipment (FCA Destination).
Fluke’s service policies generally require proof of purchase for warranty claims. The duration and coverage specifics depend on the region and purchase date. Unauthorized repairs may void the warranty. Refer to the official Fluke website or the included documentation for complete warranty details and service policy guidelines. Always follow established procedures for a smooth claim process.